规格书 |
|
工业别名 |
785901609223, XCSPA691 |
子类别 |
Switch Safety Interlock |
交货期 |
14 Days |
product certifications |
CSAUL |
vibration resistance |
5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
head type |
Key operated turret head |
head material |
PA (polyamide) |
product weight |
0.11 kg |
[Ie] rated operational current |
6 A at 120 V utilisation category AC-15, A300 conforming to EN/IEC 60947-5-13 A at 240 V utilisation category AC-15, A300 conforming to EN/IEC 60947-5-10.55 A at 125 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-10.27 A at 250 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 |
cable entry |
1 entry tapped Pg 11 |
design |
Compact |
[Ithe] conventional enclosed thermal current |
10 A |
insulation |
Double insulated |
shock resistance |
10 gn for 11 ms conforming to IEC 60068-2-27 |
product or component type |
Safety switch |
operating rate |
10 cyc/mn for maximum durability |
CAD overall depth |
30 mm |
CAD overall height |
94 mm |
safety reliability data |
B10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear) |
component name |
XCSPA |
protective treatment |
TC |
safety level |
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 |
contacts type and composition |
1 NC + 1 NO |
contacts operation |
Slow-break, make before break |
range of product |
Preventa Safety detection |
CAD overall width |
30 mm |
ambient air temperature for operation |
-25...70 °C |
mechanical durability |
>= 1000000 cycles |
minimum actuation speed |
0.01 m/s |
material |
Plastic |
IP degree of protection |
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
body material |
PA (polyamide) |
[Uimp] rated impulse withstand voltage |
6 kV conforming to EN/IEC 60947-5-1 |
locking options description |
Without locking of actuator |
electrical connection |
Terminal, 1 x 0.5...2 x 1.5 mm ² with or without cable end |
short circuit protection |
10 A cartridge fuse type gG (gl) |
actutr forcible withdrawal rtc |
10 N |
standards |
CSA C22-2 No 14EN 1088/ISO 14119EN/IEC 60204-1EN/IEC 60947-5-1EN/ISO 12100UL 508 |
[Ui] rated insulation voltage |
500 V conforming to EN/IEC 60947-1300 V conforming to CSA C22-2 No 14300 V conforming to UL 508 |
ambient air temperature for storage |
-40...70 °C |
maximum actuation speed |
0.5 m/s |
positive opening minimum force |
15 N |
cable outer diameter |
7...10 mm |
positive opening |
With NC contact |
number of poles |
2 |
class of protection against electric shock |
Class II conforming to EN/IEC 60536 |