所示图像仅为示意图。请从产品数据表中获得准确的规格。
| Type | Description |
|---|---|
| Product Category | General Purpose Relays |
| RoHS | RoHS Compliant |
| Coil Voltage | 48 VDC |
| Packaging | Bulk |
| Factory Pack Quantity | 50 |
| Relay Construction | Latching Double Coil |
| Coil Suppression Diode | No |
| Mounting | Through Hole |
| Termination Style | PC Pin |
| Maximum Current Rating | 8 |
| Maximum DC Voltage Rating | 250 |
| Type | Field Load Switching Relay |
| Coil Current | 4.7 |
| Contact Arrangement | DPST-NO |
| Push to Test Button | No |
| Minimum Operating Temperature | -40 |
| Product Length | 31 |
| Maximum Operating Temperature | 60 |
| Maximum Power Rating | 150W|2kVA |
| Contact Form | 2 Form A |
| EU RoHS | Compliant |
| Coil Resistance | 10.2K |
| Operate Time | 15 |
| DC Coil Voltage | 48 |
| Product Depth | 14 |
| Number of Terminals | 8 |
| Maximum AC Voltage Rating | 380 |
| Product Height | 11.3 |
| Seal | Sealed |
| Maximum Pick-Up Voltage | 38.4VDC |
| LED Indicator | No |
| Contact Material | Silver/Gold Flash |
| Coil Current | 4.7mA |
| Turn On Voltage (Max) | 38.4 VDC |
| Features | Sealed - Fully |
| Coil Type | Latching, Dual Coil |
| Coil Power | 240 mW |
| Relay Type | General Purpose |
| Switching Voltage | 380VAC, 250VDC - Max |
| Release Time | 10ms |
| Operating Temperature | -40°C ~ 60°C |
| Operate Time | 10ms |
| Contact Rating (Current) | 8A |
| Standard Package | 50 |
| Mounting Type | Through Hole |
| Coil Resistance | 9 kOhms |
| rohs | Lead free / RoHS Compliant |
| Operating Function | 2 Coil Latching |
| Min switching capacity | 100 mA, 5 V DC |
| Inrush current capability | 51 A (TV-3 equivalence) for 1a1b, 35 A (TV-1 equivalence) for 2a |
| Initial breakdown voltage -Between contact sets | 2,000 Vrms |
| Unit weight | Approx. 10g .353 oz |
| Initial breakdown voltage - Between contacts and coil | 3,750 Vrms |
| Reset time (latching) (at nominal voltage) | Max. 10 ms (Approx. 8 ms) |
| Current | 8 Amps |
| HP rating | 1/4 HP 125, 250 V AC |
| Coil resistance, (10%) | 10200 ohm |
| Initial insulation resistance | 1,000 Mohm (at 500 V DC) |
| Operate time (at nominal voltage) | Max. 15 ms (Approx. 10 ms) |
| MainCategory | Relays |
| Initial breakdown voltage - Between open contacts | 1,200 Vrms |
| Ambient temp | 40C to +60C, 40Fto +140F |
| Destructive Shock Resistance | Min. 980 m/s^2 {100 G} |
| Maximum allowable voltage (60C 140F) | 72 VDC |
| Contact material | Gold flash over silver alloy |
| Max switching power | 2,000 VA, 150 W |
| Surge voltage between coil and contact | Min. 6,000 V |
| Release time (without diode) (at nominal voltage) | Max. 10 ms (Approx. 8 ms) |
| Max operating speed | 20 cpm (at rated load) |
| Max switching current | 8 A |
| SubCategory | General Purpose Relay |
| Humidity | 5 to 85% R.H. |
| Set and reset voltage, (max) | 38.4 VDC |
| Initial contact resistance, max | 30 mohm |
| Functional Shock Resistance | Min. 196 m/s^2 {20 G} |
| Temperature rise (at 60C) | Max. 55C with nominal coil voltage and at 8 A switching current |
| Contact Configuration | 2A DPST-NO |
| Set time (latching) (at nominal voltage) | Max. 10 ms (Approx. 8 ms) |
| Destructive Vibration resistance | 176.4 m/s2 {18 G}, 10 to 55 Hz at double amplitude of 3 mm |
| Max switching voltage | 380 V AC, 250 V DC |
| Nominal operating current, (10%) | 4.7 mA |
| Expected life (min operations) - Mechanical (at 180 cpm) | 10^7 |
| Functional Vibration resistance | 117.6 m/s^2 {12 G}, 10 to 55 Hz at double amplitude of 2 mm |
| Expected life (min operations) - Electrical | 8 A 250 V AC (resistive): 10^5; 5 A 30 V DC (resistive): 2 10^5; 3 A 100 V AC (lamp): 3 10^4; 1 A 100 V AC (lamp): 3 10^4 |
咨询QQ