| Type | Description |
|---|---|
| product certifications | CSA 300V type 4 |
| vibration resistance | 15 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
| product weight | 0.85 kg |
| terminal identifier | (11-12)NC(13-14)NO |
| cable entry | Rubber sleeve with stepped entry, cable outer diameter: 10...22 mm |
| [Ithe] conventional enclosed thermal current | 10 A |
| mechanical interlocking | Without mechanical interlock |
| electrical circuit type | Control circuit |
| shock resistance | 100 gn conforming to IEC 60068-2-27 |
| product or component type | Pendant control station |
| rated operational power in W | 140 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C140 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C95 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C |
| class of protection against electric shock | Class II |
| control station colour | Yellow |
| control button type | First pushbutton raise, slowSecond pushbutton lower, slow |
| resistance across terminals | <= 25 MOhm |
| protective treatment | TH |
| contacts operation | Snap action |
| range of product | Harmony XAC |
| operating force | 7 N for pushbutton |
| ambient air temperature for operation | -25...70 °C |
| mechanical durability | 1000000 cycles |
| control station name | XACB |
| IP degree of protection | IP65 conforming to IEC 60529 |
| control station type | Double insulated |
| contact code designation | A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix AQ600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A |
| enclosure type | Complete ready for use |
| IK degree of protection | IK08 conforming to EN 50102 |
| enclosure material | Glass reinforced polyester |
| terminals description ISO n °1 | (1-2-3-4)OC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| short circuit protection | 10 A fuse protection by cartridge fuse type gG |
| control station application | Control of single speed hoist motor |
| standards | CSA C22-2 No 14EN/IEC 60204-32EN/IEC 60947-5-1UL 508 |
| [Ui] rated insulation voltage | 500 V (degree of pollution: 3) conforming to IEC 60947-1 |
| ambient air temperature for storage | -40...70 °C |
| rated operational power in VA | 100 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load)450 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load)50 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load)750 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load) |
| control station composition | 2 pushbuttons |
| connections - terminals | Screw clamp terminals, connection capacity: 1 x 2.5 mm ² with or without cable endScrew clamp terminals, connection capacity: 2 x 1.5 mm ² with or without cable end |
| contact block name | XESB2011 for reversing operation |