所示图像仅为示意图。请从产品数据表中获得准确的规格。
| Type | Description |
|---|---|
| 工作温度 | 0 to 50 °C |
| 标准包装 | Bulk |
| 系列 | * |
| 其他名称 | WAZ1CAC |
| RoHS指令 | Lead free / RoHS Compliant |
| Output voltage, note | 0...10 V |
| Offset voltage | max. 0.05 V |
| Output signal limit | Approx. 13 V or 24 mA |
| Net weight | 108 g |
| Input frequency | 50...60 Hz |
| 版本 | WAVESERIES, Current monitoring, 0...1 A AC/ 0...5 A AC/ 0...10 A AC, 1, 1, Tension clamp connection |
| GTIN (EAN) | 4032248173341 |
| load impedance voltage | ≥ 1 kΩ |
| 类型 | WAZ1 CMA 1/5/10A ac |
| Number of outputs | 1 |
| Length (inches) | 2.835 inch |
| 输出电流 | 0(4)...20 mA |
| eClass 7*1 | 27-37-18-02 |
| Operating temperature | 0 °C...50 °C |
| Long specification | Monitoring component for AC currents up to 10A with standard signal output and electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents 0...1 A / 0...5 A / 0...10 A. Standardised analogue current/voltage signals are available on the output side. Input and output ranges can be adjusted via DIP switches. The 24 VDC power is supplied over the output circuit. The input and outputs are designed with 6 kV of electrical isolation. Add-on housing for TS35 rail mounting Dimensions: L/W/H 72/ 22.5/ 92.4 mm Tension-clamp connection / Nominal cross-section 1.5 mm2Protection degree: IP 20 Input 0...1 A / 0...5 A / 0...10 A AC switchable 50 / 60 Hz Voltage of measuring circuit 250 V AC Output 0(4)...20 mA / 0...10 V Load resistance < 600 Ohm Strom >1 kOhm / voltageTransmission error < 0,5% v. E. Temperature coefficient 200 ppm / K Step response time typ. 700 msAuxiliary power 24 VDC +/- 10 % via output circuit Ambient temperature range 0 °C...+50 °C Secure isolation EN 50178, 2-way isolation up to 6 kVTest voltage 4 kV input against outputRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULus Type WAZ1 CMA 1/5/10A ac |
| eClass 8*1 | 27-37-18-02 |
| ETIM 4*0 | EC002048 |
| Input current | 0...1 A AC/ 0...5 A AC/ 0...10 A AC |
| load impedance current | ≤ 600 Ω |
| Depth (inches) | 3.638 inch |
| Clamping range, rated connection, min | 0.5 mm² |
| Package insert | instruction sheet.pdf |
| eClass 6*2 | 27-21-09-02 |
| 长度 | 72 mm |
| Storage temperature | -20 °C...70 °C |
| Declaration of Conformity | Declaration of Conformity |
| Number of inputs | 1 |
| Width (inches) | 0.886 inch |
| 宽度 | 22.5 mm |
| MTTF | 533 Years |
| Status indicator | LED ON: OK; FLASHING: signal out of range;LED OFF: Error |
| Short specification | Monitoring component for AC currents up to 10A with standard signal output and electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents 0...1 A / 0...5 A / 0...10 A. Standardised analogue current/voltage signals are available on the output side. Input and output ranges can be adjusted via DIP switches. The 24 VDC power is supplied over the output circuit. The input and outputs are designed with 6 kV of electrical isolation. |
| ETIM 6*0 | EC002048 |
| Clamping range, rated connection | 1.5 mm² |
| Offset current | max. 100 µA |
| 深度 | 92.4 mm |
| eClass 9*0 | 27-37-18-02 |
| ETIM 5*0 | EC002048 |
| Descriptive text accessories | Cross-connectors for power supplies and markers – refer to Accessories |
| Clamping range, rated connection, max | 2.5 mm² |
| Type of connection | Tension clamp connection |
| ROHS | Conform |